Boiler and hot water heating: repair, service and installation
A boiler heats water and pumps it around the house. When part of the house goes cold, the boiler itself is often fine and the fault is in a pump, a zone valve or air in the lines. We find which.
What we work on: Natural gas, propane and electric boilers. Cast iron boilers and wall-hung condensing boilers, including combination units that also heat tap water.
Leave the building first. Call FortisBC at 1-800-663-9911 or 911 from outside. Call us after it is safe.
Installation
- A written estimate for the new boiler, sized for the house and the heating it feeds.
- The old boiler removed and the new one piped in, with new pumps, valves and expansion tank where they are needed.
- Venting, condensate drain and gas connection, with the gas permit taken out by us.
- The system filled, purged of air, started up and tested zone by zone.
Yearly service
- Burner, igniter and flame sensor checked and cleaned.
- Heat exchanger, venting and combustion air checked.
- Pressure relief valve, expansion tank and system pressure checked.
- Pumps, zone valves and low-water protection checked.
- A written record of what was checked and what we found.
Repairs
- Circulating pumps and zone valves.
- Expansion tanks, pressure relief valves and fill valves.
- Igniters, flame sensors, gas valves and control boards.
- Leaks at fittings, valves and radiators, and air-bound zones.
What is it doing?
The usual causes, and what to do first. A visit confirms which one it is.
| Symptom | What it often is | What to do |
|---|---|---|
| No heat anywhere | The boiler is locked out, has lost pressure, or is not getting a call for heat from the thermostat. | Note any code on the display. Then call. |
| One room or one floor is cold | Air in that loop, a stuck zone valve or a failed pump on that zone. | Book a visit. |
| Banging or gurgling in the pipes | Air in the system or low water pressure. | Book a visit. Do not add water to a hot boiler. |
| Water dripping at the boiler | A relief valve that is weeping because the expansion tank has failed, or a leaking fitting. | Call. A relief valve should not drip. |
| Pressure keeps dropping | A leak somewhere in the system, or a failed expansion tank. | Book a visit. |
What it costs
- Service call, first hourIncludes dispatch. Regular hours.
- Call for price
- Each additional hourRegular hours.
- Call for price
Prices are before GST. Repairs and yearly servicing are both billed at this hourly rate. Parts and materials are extra and explained before they are used. A new installation is priced by written estimate. All rates, including after hours.
Repair it or replace it?
Boilers last a long time, and most of the parts around them can be replaced on their own. A failed pump or zone valve is not a reason for a new boiler.
A leaking or cracked heat exchanger usually is. So is a boiler that can no longer be made to vent safely.
In a shared building, a boiler change is a planned project. We give the strata or the owner a written estimate with the scope spelled out.
Questions
Do you work on in-floor (radiant) heating?
Yes. The boiler, the pumps, the mixing valves and the manifolds that feed the floor loops.
Do you look after boilers in strata and commercial buildings?
Yes. Pure Mechanical Group Ltd. services boilers in houses and in multi-unit buildings.
How often should a boiler be serviced?
Once a year, the same as any gas heating appliance.
My boiler also heats my tap water. Do you work on those?
Yes, combination boilers too. For a separate water heater, see waterheaterinstallation.ca.
Tell us what it is doing.
Call, or send the form and our office calls you back to confirm a time and the rate.